Myron L Ultrameter II

+ Free Shipping

Discover the Myron L Ultrameter II, a high-performance handheld device that offers precise measurement of pH, conductivity, TDS, and ORP. Ideal for reliable water quality testing in labs,

Myron L UltraMeter II

At Ultratec Water Treatment Company UAE, we are excited to introduce the Ultrameter II series, the pinnacle of handheld water quality testing devices. This innovative series combines the functions of up to seven different instruments into a single, cost-effective, high-performance tool, making it the ultimate choice for any water quality meter Myron offers.

The Myron Ultrameter 2 Water Testing Equipment
The Myron Ultrameter 2 is a top-notch, portable digital water quality meter that precisely measures various parameters such as pH, conductivity, TDS, and ORP. This compact and efficient tool functions as a Myron Ultrameter 2 pH Meter, Ultrameter 2 Conductivity Tester, TDS Meter, and ORP Meter, offering outstanding accuracy and user-friendly operation for diverse applications.

Unmatched Accuracy for Precision Water Testing
The Myron Ultrameter 2 Digital Water Analyzer delivers exceptional accuracy with a tolerance of ±1% of the reading. This precision is achieved through its advanced four-electrode conductivity cell, sophisticated pH/ORP sensor, and cutting-edge microprocessor technology. The four-digit LCD display ensures clear and accurate readings up to 9999. Each unit is factory-calibrated with NIST-traceable solutions, and we provide traceability certification to maintain the highest calibration standards for reliable results in all settings.

Innovative Engineering for Versatile Use
Designed for simplicity and efficiency, the Myron Ultrameter 2 streamlines water quality testing:

  1. Fill the cell cup.
  2. Press the parameter key.
  3. Take the reading.

With automatic temperature compensation and range selection, the Ultrameter 2 Water Testing Equipment is perfect for one-handed use, whether in a laboratory, industrial setting, or remote field location.

Effortless Calibration with Myron Ultrameter 2 Calibration
Calibration is straightforward with the Myron Ultrameter 2. Simply adjust the calibration by pressing the keys to match our NIST-traceable Standard Solution. Display prompts guide you through pH calibration, ensuring the correct buffer is used. Additionally, internal electronic settings allow for field calibration and easy monitoring of the Myron Ultrameter 2 pH Meter or ORP Meter sensor’s lifespan.

New! FCE™ FAC Readings
Our FCE function provides accurate FAC measurements by analyzing ORP and its effectiveness in relation to pH. Unlike traditional DPD kits or colorimeters, the FCE function evaluates the actual chemistry of the source water, including real-time changes, offering a more precise assessment of disinfection power.

High Performance, Affordable Price
The Myron Ultrameter 2 Portable Water Quality Analyzer offers outstanding performance at a budget-friendly cost. Its ultra-fast, user-friendly design ensures you get the best return on your investment. To learn more about how the Ultrameter 2 Water Testing Equipment can elevate your water quality analysis, contact us at Ultratec Water Treatment Company UAE today.

Ultrameter™ II 6PFCᴱ & 4P Specifications
Specification Details
Display 4 Digit Liquid Crystal Display
Dimensions (L x W x H) 196 x 68 x 64 mm (7.7 x 2.7 x 2.5 inches)
Weight 352 g (12.4 oz.)
Case/Cell Material VALOX* (Sabic Innovative Plastics)
Cell Capacities pH/ORP: 1.2 ml (0.04 oz.)
Cond/TDS/Res: 5 ml (0.2 oz.)
Power 9V alkaline battery
Battery Life >100 hours (5000 readings)
Operating/Storage Temperature 0 – 55°C (32 – 132°F)
Protection Ratings IP67/NEMA 6
Waterproof Depth 1 meter (3 feet)

Functional Specifications

Parameter Range Resolution Accuracy Auto Temp Compensation Adjustable Temp Compensation Other Features
Conductivity 0–9999 μS/cm; 10–200 mS/cm (5 autoranges) 0.01 (<100 μS); 0.1 (<1000 μS); 1 (<10 mS); 0.01 (<100 mS); 0.1 (<200 mS) ±1% of reading 0–71°C (32–160°F) 0–9.99%/°C Preprogrammed ratios: KCl, 442*, NaCl
Adjustable ratio factor: 0.20–7.99
TDS 0–9999 ppm; 10–200 ppt (5 autoranges) 0.01 (<100 ppm); 0.1 (<1000 ppm); 1 (<10 ppt); 0.01 (<100 ppt); 0.1 (<200 ppt) ±1% of reading 0–71°C (32–160°F) 0–9.99%/°C Preprogrammed ratios: KCl, 442*, NaCl
Adjustable ratio factor: 0.20–7.99
Resistivity 10 KΩ–30 MΩ 0.01 (<100 KΩ); 0.1 (1 MΩ) ±1% of reading 0–71°C (32–160°F) 0–9.99%/°C
pH 0–14 pH 0.01 pH ±0.01 pH** 0–71°C (32–160°F)
ORP ±999 mV 1 mV ±1 mV
Free Chlorine (FCE™) 0.00–9.99 ppm (specific ORP and pH ranges) 0.01 ppm <1.00 ppm ±0.3 ppm**
≥1.00 ppm ±0.2 ppm
0–71°C (32–160°F)
Temperature 0–71°C (32–160°F) 0.1°C/F ±0.1°C

 

Applications for Myron Ultrameter 2

  • Irrigation Water: Monitor and ensure the quality of water used for irrigation.
  • Hydroponics: Optimize nutrient solutions for hydroponic growing systems.
  • Laboratories: Conduct precise water quality analysis with the Ultrameter 2 Water Quality Meter Myron.
  • Homeland Security: Ensure water safety and quality in critical infrastructure.
  • Reverse Osmosis: Verify the effectiveness of reverse osmosis systems.
  • Deionization: Check the quality of deionized water for various applications.
  • Wastewater: Analyze and manage wastewater treatment processes.
  • Cooling Towers: Monitor water quality in cooling tower systems.
  • Environmental: Assess water quality in environmental monitoring and studies.
  • Desalination: Ensure the effectiveness of desalination processes.
  • Fountain Solutions: Maintain the quality of water used in decorative fountains.

bluDock™ Accessory Kit
This kit includes the bluDock, software for Macintosh/PC (Guardian2™) to download data, and detailed printed instructions.
Model: BLUDOCK

NIST Traceability Certificates
Certificates confirming the NIST traceability of your Myron Ultrameter 2 can be obtained. Be sure to request these when placing your instrument order.
Model: MC

Conductivity Standard Solutions
To ensure accurate readings and regular calibration of conductivity/TDS measurements, use our NIST-traceable standard solutions. Recommended options include: KCl-7000 (7 mS), 442-3000 (TDS), or NaCl-14.0 (mS). Available sizes: 2 oz/59 mL, 1 qt/1 L, and 1 gal/3.8 L.

pH Buffers
For maintaining precise pH and ORP readings, regular calibration with pH 7 Buffer is crucial. Our pH Buffers (4, 7, and 10) are NIST-traceable and come in 2 oz/59 mL, 1 qt/1 L, and 1 gal/3.8 L sizes.

pH/ORP Sensor Storage Solution
Available in 2 oz/59 mL, 1 qt/1 L, and 1 gal/3.8 L sizes.
Models: SS20Z, SSQ, and SSG

NIST Traceability Certificates for Solutions
Certificates of NIST traceability for pH Buffers and Conductivity Standard Solutions can be provided. Request these when ordering your solutions.
Model: SC

Protective Cases

  • Small Hard Case
    Model: UPP
  • Kit Hard Case
    This case includes three pH buffers (4, 7, and 10), one pH/ORP storage solution, and two standard solutions (KCl-7000 and 442-3000), all in 2 oz/59 mL bottles.
    Model: PKUU
  • Soft Protective Case
    Constructed from padded Nylon with a belt clip for easy carrying. Available in blue and desert tan.
    Models: UCC (Blue), UCCDT (Desert Tan)

Replacement pH/ORP Sensor
This user-replaceable sensor features a unique porous liquid junction for improved accuracy.
Model: RPR

ORP Sensor Conditioner Solution
For maintaining precise ORP readings.
Model: ORPCOND


Shopping Cart